PMR10H / PMR15H / PMR20H give industrial gateways, data-acquisition terminals and compact controllers a 10–20 W isolated on-board AC/DC front end that connects directly to single-phase AC mains. For devices fed from a cabinet 24 VDC bus, select from DC/DC and isolated modules instead.
All four connect field devices to a host system. What separates them is not the protocol, but where the power comes from and how much the device needs.
Modbus, PROFIBUS and EtherNet/IP conversion; multiple serial and Ethernet ports kept permanently online, with the load dominated by communications and the processor.
LTE / 5G data links and remote maintenance; transmit peaks run far above average consumption, so the supply must be sized on peak current and hold-up time.
DI/DO, analog and temperature inputs; channel count and isolation domains set the load on the 5 V, 3.3 V and isolated rails.
Local logic, data buffering and alarms; processor power, heat dissipation and relay actuation are the main design constraints.
85–305 VAC covers single-phase mains across regions, cutting the number of regional part numbers and adapter variants.
−40 to +85 °C, dust- and moisture-resistant; suited to control cabinets, distribution boxes and small outdoor enclosures.
Module-level CISPR 32 / EN 55032 Class B results cut EMC components and debugging effort.
One family spans light nodes to multi-interface controllers, so load growth does not mean redesigning the power front end.
Most power problems in industrial gateways are not a lack of wattage, but a misunderstood supply source and conditions left out of the calculation.
Production gateways usually accept 12 V / 24 VDC or a wide DC input, with AC/DC conversion already done in the cabinet. Reading “installed in a cabinet” as “needs AC/DC” leads to the wrong selection and repeated prototype rounds.
Work out which of the four supply sources applies, then decide whether on-board AC/DC is needed.Industrial sites bring voltage dips, inductive-load switching and lightning-induced surges. Wide input is only the baseline; MOVs, TVSs, fuses and filtering still have to be assessed at end-product level.
With external protection circuitry, EFT withstand reaches ±4 kV and surge withstand ±2 kV.Cabinet temperature rise and restricted natural convection can push the module's case temperature well above what bench testing suggests. Size against the derating curve and keep case temperature at or below 95 °C.
−40 to +85 °C, 95 °C maximum case temperature.RS-485, CAN and analog acquisition carry ground-potential differences and noise. Use isolated DC/DC and digital isolators for the communications domain, and LDOs plus filtering on the analog rails.
Input-to-output 4000 VAC, 1 minute.Equipment is expected to last a decade or more, and load grows as model configurations expand. Judge it on MTBF and warranty, and reserve power, thermal headroom and PCB area early in the design.
MTBF > 1,500,000 h (calculated) · 3-year warrantyThe dividing line is not the enclosure, but whether AC/DC conversion happens inside the device or inside the cabinet. Take the wrong path and even the right module ends up in the wrong place.
Figure 1. Internal AC input path: single-phase mains enters the device, where the PMR10H-120 provides isolation and the 12 V conversion stage before the rails are distributed to logic, communications, analog and actuation loads. Continuous load is best kept within 5–8 W.
Figure 2. Cabinet 24 VDC bus path: AC/DC conversion is already handled in the cabinet and the PMR family is not part of this segment. Where the device still needs 5 V, 3.3 V or an isolated domain, select from FAVOTEK DC/DC and isolated modules.
85–305 VAC wide input, 12 V / 833 mA output and 4000 VAC isolation, in an encapsulated package suited to cabinets and enclosures (shown here in CT terminal-block form). Continuous load is best kept within 5–8 W, leaving headroom for temperature rise, communications peaks and later configuration changes.
All three power tiers share one design approach; they differ in power, thermal headroom and overvoltage category. Mounting style then follows from how the cabinet is wired.
| Model | Power / Output | Efficiency / Capacitive Load | OVC / Dimensions (PCB version) |
|---|---|---|---|
| PMR10H-120 | 10 W · 12 V / 833 mA | 85% · 2000 µF | OVC II · 45.7 × 25.4 × 21.5 mm |
| PMR15H-120 | 15 W · 12 V / 1250 mA | 86% · 4000 µF | OVC III · 52.4 × 27.2 × 24 mm |
| PMR20H-120 | 20 W · 12 V / 1670 mA | 86% · 2500 µF | OVC III · 52.4 × 27.2 × 24 mm |
The same family is offered in PCB-encapsulated, CT terminal-block and CR DIN-rail form factors; output voltage follows the ordered part number.




Selection check: Is the device itself fed from 24 VDC or a 9–36 VDC wide DC input? AC/DC conversion has usually already been done in the cabinet — select from FAVOTEK DC/DC, isolated modules and POL.
Parameters based on the PMR10H V1.62 / PMR15H V1.72 / PMR20H V1.73 datasheets (11/2026, 11/2026, 10/2026); CT/CR mounting accessories reduce efficiency by approximately 2%. Contact FAVOTEK to confirm full part numbers and certification status.
The value of a module is not only in its numbers. It is in giving the equipment maker isolation, EMC, safety and security of supply in one package. One 10 / 15 / 20 W family means less repeated validation.
The encapsulated construction resists dust and moisture and operates from −40 to +85 °C, suited to control cabinets, distribution boxes and small outdoor enclosures.
Three 10 / 15 / 20 W tiers share one design approach, so load growth means moving up a tier rather than redesigning the front end and the enclosure.
Class B without external circuitry, wide input and built-in protection reduce EMC filtering, debugging and certification rework.
Module-level safety, EMC and reliability data are in place for end-product risk assessment; end-product certification still depends on system validation.
Confirm where the power comes from, continuous and peak power, mounting method and certification targets.
Reference circuits, isolation partitioning, input protection and PCB layout guidance.
Class B results, pre-compliance test items and end-product certification boundaries.
Sample evaluation, test data and engineering support for the end-product certification path.
10 W rated × 50–80% ≈ 5–8 W. Keep continuous load inside this band to leave headroom for temperature rise, communications peaks and aging. Above 8 W, verify peak current and thermal performance first, then consider PMR15H.
If continuous load stays close to 10 W, LTE transmit peaks are pronounced, relays actuate frequently, cabinet temperature runs high, or the overvoltage category has to be OVC III, evaluate PMR15H / PMR20H directly to avoid a later board revision.
Tell us where the power comes from, continuous and peak power, output rails, isolation requirements, mounting method and certification targets. We will work through whether PMR fits, or whether the design should move to DC/DC.